<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Dry Eye - Insight Medical Technologies</title>
	<atom:link href="https://insightmedical.ca/product-category/diagnostic-equipment/dry-eye/feed/" rel="self" type="application/rss+xml" />
	<link>https://insightmedical.ca</link>
	<description>Your Consultative Ophthalmic Equipment Dealer Since 2009</description>
	<lastBuildDate>Thu, 16 Nov 2023 00:07:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>

<image>
	<url>https://insightmedical.ca/wp-content/uploads/2017/08/cropped-Logo-HQ-32x32.jpg</url>
	<title>Dry Eye - Insight Medical Technologies</title>
	<link>https://insightmedical.ca</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Visionix VX 120+ Dry Eye Multifunction ARK</title>
		<link>https://insightmedical.ca/product/visionix-vx-120-dry-eye-multifunction-ark/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=visionix-vx-120-dry-eye-multifunction-ark</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Tue, 17 Oct 2023 21:15:21 +0000</pubDate>
				<guid isPermaLink="false">https://insightmedical.ca/?post_type=product&#038;p=9554</guid>

					<description><![CDATA[<p>The screening services provided by the VX 120+ Dry Eye give you the opportunity to alert your patients of pathologies like glaucoma, cataracts, keratoconus, as well as correcting vision defects including those affecting night vision, and in so doing complete the panel of services that you offer as an optician / optometrist. Earning client loyalty through competent care and good relationships becomes easier. By giving the client more time, with more information about their visual health, they will naturally recognize your long-term added value.</p>
<p>The post <a href="https://insightmedical.ca/product/visionix-vx-120-dry-eye-multifunction-ark/">Visionix VX 120+ Dry Eye Multifunction ARK</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="ue-grid-item">
<div class="main-features-title">
<h2>You can now screen and monitor eye pathologies inclusive the dry eye syndrome.</h2>
</div>
<div class="content-features">
<ul>
<li>Non-Invasive Tear Breakup Time: A test that processes the movement of the rings on the eye and gives the speed of tear film breakup between two blinks.</li>
<li>Meibomian glands: The color camera allows you to make a photo gallery of the parts of the eye and to focus on the meibomian glands area.</li>
<li>Tear Meniscus value: Using the manual zoom of the color camera, you can measure the height of the tear meniscus to complete the test.</li>
</ul>
</div>
</div>
<div class="ue-grid-item">
<div class="main-features-title">
<h2>A device for you to take care of the visual health of all your patients.</h2>
</div>
<div class="content-features">
<ul>
<li>You will improve your daily practice</li>
<li>You will provide better service and create differentiation</li>
<li>You will have more patients and have the opportunity to sell night glasses</li>
<li>You will receive better trust and an enhanced reputation</li>
</ul>
</div>
</div>
<div class="ue-grid-item">
<div class="main-features-title">
<h2>Increase your quality of service by using a complete diagnostic tool</h2>
</div>
<div class="content-features">
<ul>
<li>Distinguish yourself from your competitors and be a recognized vision expert</li>
<li>Reinforce your position as a specialist</li>
<li>Create and/or increase relationships with ophthalmologists</li>
</ul>
</div>
</div>
<div class="ue-grid-item">
<div class="main-features-title">
<h2>Perform a complete examination of the anterior segment of the eye</h2>
</div>
<div class="content-features">
<ul>
<li>Cataracts: Screening and approving candidates for Premium implants</li>
<li>Refractive: Screening and approving candidates for surgery</li>
<li>Glaucoma: Screening and monitoring</li>
<li>Adaptation of rigid and scleral contact lenses</li>
<li>Keratoconus: Screening, stage classification, and monitoring</li>
<li>Identifying refraction needs that are linked to night vision</li>
<li>Also provides complete readings for refraction and keratometry</li>
<li>Screen and monitor Dry Eye Syndrome (DES)</li>
</ul>
</div>
</div>
<div class="ue-grid-item">
<div class="main-features-title">
<h2>Obtain precise measurements and a visual health assessment of the client</h2>
</div>
<div class="content-features">
<ul>
<li>Accurate vision for your patients with customized glasses that may even correct night vision if needed</li>
<li>Create satisfaction and client retention</li>
<li>Reinforce wearer’s feeling of security and trust</li>
<li>Adaptation of premium products</li>
</ul>
</div>
</div><p>The post <a href="https://insightmedical.ca/product/visionix-vx-120-dry-eye-multifunction-ark/">Visionix VX 120+ Dry Eye Multifunction ARK</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mediworks D-130 Dry Eye Diagnostic System</title>
		<link>https://insightmedical.ca/product/mediworks-d-130-dry-eye-diagnostic-system/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=mediworks-d-130-dry-eye-diagnostic-system</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Thu, 17 Feb 2022 17:41:12 +0000</pubDate>
				<guid isPermaLink="false">https://insightmedical.ca/?post_type=product&#038;p=9440</guid>

					<description><![CDATA[<p class="product-title">Fast, Comprehensive, and Easy to use Dry Eye Diagnostics straight out of the comfort of your exam lane.</p>
<p class="product-description">The Mediworks D-130 Corneal Analyzer attaches directly to your Mediworks S391 Firefly Slit Lamp expanding its capabilities and allowing the measurement of 7 new dry eye exams.</p>
<p><a href="https://insightmedicaltechnologies-my.sharepoint.com/:b:/g/personal/tyler_insightmedical_ca/EYVcrGYqrlRClfSc5SxxlTQBu9J1TlhAE4g2qghFnJkg1w?e=vHDw4M">Click here for product brochure</a></p>
<p>The post <a href="https://insightmedical.ca/product/mediworks-d-130-dry-eye-diagnostic-system/">Mediworks D-130 Dry Eye Diagnostic System</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="comp PureText comp" data-id="l=RgPTo88">
<div class="p-txt">
<div class="al-left"></div>
</div>
</div>
<div class="comp RightImageLeftTextRBImg comp" data-id="lJ3eus3fh">
<div class="p-txt left-col al-flex-50">
<div class="al-top">
<p><strong>Mediworks D-130 Dry Eye Diagnostic Device.</strong></p>
<p>The D-130 functions as an excellent diagnostic device right out of your exam lane. The D-130 dry eye diagnostic system enhances accurate diagnoses and earlier intervention, providing you guidance for customized treatment for each patient.</p>
<p><strong>Platform for Comprehensive Ocular Surface Examination:</strong></p>
<p>&#8211; Dry eye diagnosis/Anterior Segment Photography/Lens fitting/<br />
Patient management/Telemedicine</p>
<p>&#8211; Guided examination: Providing a comprehensive report covering 7 dry eye diagnoses utilizing non-invasive examinations for quantitative data.</p>
<p>&#8211; Fully-automatic Firefly digital module, easy operation without the need to change parameter settings.</p>
<p>&#8211; High quality optics and built-in yellow filter efficiently increase the accuracy of lens fittings.</p>
<p>&#8211; Smart patient management system (DICOM supported).</p>
</div>
</div>
</div>
<div class="comp TopImageBottomText comp" data-id="lQT1G4fig">
<div class="p-img">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210818044048707.jpg" alt="3.jpg" />Due to various causes of Dry Eye Disease, a traditional eye examination is often difficult to find out the cause and quantify for the diagnosis and treatment options.</p>
<p>Mediworks D-130 Dry Eye Diagnostic System can provide a standardized examination and quantified causes for the evaluation of Dry Eye Disease.</p>
</div>
</div>
<div class="comp TopImageBottomText comp" data-id="lLzmdmVHF">
<div class="p-img">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325050532451.png" alt="未标题-2.png" /><strong>AI Non-Invasive Break Up Time:</strong></p>
<p>After capturing a video, Mediviews AI will automatically generates results for both NIBUT and Tear Meniscus Height.</p>
<p>The AI identifies the break-up area and analyzes NIBUT automatically, the fully automated analysis system provides efficient quantified evaluation for the overall stability of the tear film. The AI will automatically acquire the initial break up time, the average break up time, the break up distribution, the break up area percentage curve, and the time distribution.</p>
<p>&#8211; Grade 0: Normal, First Rupture Time: 10 s Average Rupture Time: 14 s<br />
&#8211; Grade 1: Warning, First Rupture Time: 6-9 s Average Rupture Time: 7-13 s<br />
&#8211; Grade 2: Dry eye, First Rupture Time: 5 s Average Rupture Time: 7 s</p>
</div>
</div>
<div class="comp LeftImageRightText comp" data-id="lS7wSWI7X">
<div class="p-img al-flex-50">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325030458305.png" alt="4.png" />The Mediworks D-130 adopts a Placido ring projection system with self-emitting visible light to conduct NIBUT examination, the examination scope measures up to an 8mm cornea diameter which brings much more comprehensive diagnostic outcome.</p>
<p>The non-invasive examination avoids the irritation brought to the patient through the traditional method of Cornea Sodium Fluorescein Staining.</p>
</div>
</div>
<div class="comp TopImageBottomText comp" data-id="la9V6QXML">
<div class="p-img"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325073437810.png" alt="5.png" /></div>
<div class="p-txt">
<div class="al-left">
<h4 class="al-txt sub-title"></h4>
</div>
</div>
</div>
<div class="comp LeftTextRightImage comp" data-id="lpA2tBILd">
<div class="p-txt al-flex-50">
<div class="al-top">
<p class="al-txt main-title"><strong>AI Non-Invasive Tear Meniscus Height</strong></p>
<p>AI identification system automatically depicts the Tear Meniscus area and measures the tear height automatically (Normal: ≥0.2mm).</p>
<p>Evaluate tear secretion amount and continuity objectively. More efficient and less irritation compared with the traditional Schirmer’s test.</p>
</div>
</div>
<div class="p-img al-flex-50"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325031245922.png" alt="6.png" /></div>
</div>
<div class="comp MultiColProduct2 comp" data-id="lbzb9jA2U">
<div class="product-col">
<div class="p-img"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325031513544.png" alt="123.png" /></div>
<div class="p-txt">
<p class="al-txt content-text preline">(Insufficient tear secretion)</p>
</div>
</div>
<div class="product-col">
<div class="p-img"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325031525415.png" alt="11.png" /></div>
<div class="p-txt">
<p class="al-txt content-text preline">(Abnormal dynamics and conjunctival chalasis)</p>
<p><strong>Evaluation of Meibomian Glands Function:</strong></p>
<p>Capture 3 separate images with one click (Original, Enhanced, Results)</p>
<p>The AI identification system automatically analyzes meibomian glands loss caused by meibomian glands dysfunction with precise and quantified diagnosis results.</p>
<p>The built-in infrared lighting system helps doctors obtain a larger scope of the meibomian glands.</p>
<p>Adjustable depth of field makes the glands more prominent and distinguishable against the background.</p>
<p>&#8211; Grade 0: No Meibomian Glands Loss<br />
&#8211; Grade 1: Meibomian Glands Loss ＜ 1/3<br />
&#8211; Grade 2: Meibomian Glands Loss 1/3-2/3<br />
&#8211; Grade 3: Meibomian Glands Loss ＞2/3</p>
</div>
</div>
</div>
<div class="comp LeftImageRightText comp" data-id="ly3z3185w">
<div class="p-img al-flex-50"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210818044231436.jpg" alt="4.jpg" /></div>
<div class="p-txt al-flex-50">
<div class="al-top">
<p>&nbsp;</p>
</div>
</div>
</div>
<div class="comp MultiColProduct2 comp" data-id="lL9a8Whiz">
<div class="product-col">
<div class="p-img"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210818044553879.png" alt="103.png" /></div>
<div class="p-txt">
<p class="al-txt content-text preline">(Meibomian glands loss)</p>
</div>
</div>
<div class="product-col">
<div class="p-img"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210804054356285.png" alt="104.png" /></div>
<div class="p-txt">
<p class="al-txt content-text preline">(Image of Meibomian Glands under high-magnification)</p>
<p><strong>Lipid Layer Thickness:</strong></p>
<p>The D-130’s built in white ring projection system ensures a larger examination area compared to the Placido rings. By recording a video of the Lipid Layer thickness and comparing results to our built in normative database it is helpful for judging the patients potential MGD.</p>
<p>&#8211; Grade 1: &lt;30<br />
&#8211; Grade 2: 30-60<br />
&#8211; Grade 3: 60-80<br />
&#8211; Grade 4: &gt;80</p>
</div>
</div>
</div>
<div class="comp LeftTextRightImage comp" data-id="lFluN9rge">
<div class="p-img al-flex-50">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210224082207503.png" alt="10.png" /></p>
<p><strong>Eyelid Margin:</strong></p>
<p>The professional design of the Mediworks optical system can provide HD digital images that remains clear and sharp even when zoomed in, this allows the D-130 to meet the examination requirements of the overall shape of the eyelids margin and its slight change.</p>
<ol>
<li>Normal including (Ophthalmic embolism bright, transparent)</li>
<li>Mild including (gland cap crown &#8211; glandular prominent)</li>
<li>Moderate including (glandular fat plug &#8211; disappearance of the marginal mucosa, hyperkeratosis)</li>
<li>Severe including (uneven margins, disappearance of the meibomian glands &#8211; posterior margin Blunt round, thickening, new blood)</li>
</ol>
</div>
</div>
<div class="comp LeftImageRightText comp" data-id="lZlXGbgH2">
<div class="p-img al-flex-50">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210224082701992.png" alt="11.png" /><strong>AI Analysis of Conjunctival Hyperemia:</strong></p>
<p>Normal: ≤2 Abnormal: &gt;2</p>
<p>The unique AI identification system can help identify and calculate percentages of conjunctival congestionand ciliary congestion to evaluate severity of eye congestion.</p>
</div>
</div>
<div class="comp LeftTextRightImage comp" data-id="lz14FXDhe">
<div class="p-img al-flex-50"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210325051552693.png" alt="12.png" /></div>
</div>
<div>
<p><strong>Cornea Sodium Fluorescein Staining:</strong></p>
<p>Effectively increases positive rate of early corneal epithelial staining using the built-in yellow filter paired with the cobalt-blue filter to make the corneal sodium fluorescein images more clear</p>
</div>
<div></div>
<div class="comp LeftImageRightText comp" data-id="l3DFBWwZE">
<div class="p-img al-flex-50"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210224084043666.png" alt="14.png" /></div>
</div>
<div class="comp PureText comp" data-id="lzEemmb9M">
<div class="p-txt">
<div class="al-left">
<p class="al-txt main-title"><strong>Comprehensive Dry Eye Evaluation Report</strong></p>
<p>Convenient Medical Consultation on Dry Eye Syndrome in an easy to read PDF.</p>
</div>
</div>
</div>
<div class="comp TopImageBottomText comp" data-id="lhtCs8LXc">
<div class="p-img"><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210818044732325.png" alt="未标题-5.png" /></div>
</div>
<div>
<p><strong>Smart Patient Management system:</strong></p>
</div>
<div></div>
<div class="comp MultiColProduct2 comp" data-id="lFQYuCRwW">
<div class="product-col">
<div class="p-img">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210205023422784.jpg" alt="15.jpg" /></p>
<p><strong>Comparison of Patient records:</strong></p>
<p>The Smart Patient Management system supports repeated comparison among medical records to help doctors develop customized treatment plans and evaluate treatments over a period of time.</p>
<p>&nbsp;</p>
</div>
</div>
<div class="product-col">
<div class="p-img">
<p><img decoding="async" class="al-img cover" src="https://www.mediworks.biz/attachments/artl-editor/20210202061521547.png" alt="9.png" /></p>
<p>The Mediview Patient Management system allows doctors to build and edit medical records, note patients’ situation via the software, and quickly search the patient case.</p>
<p>&nbsp;</p>
</div>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lX4JeeFFY">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title">Specifications</h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>Microscope</th>
</tr>
</tbody>
<tbody>
<tr>
<td>Microscope Type</td>
<td>Galilean Type</td>
</tr>
<tr>
<td>Magnification Change</td>
<td>Revolving Drum 5 steps</td>
</tr>
<tr>
<td>Total Magnification</td>
<td>6.3X, 10X, 16X, 25X, 40X</td>
</tr>
<tr>
<td>Optical Resolution</td>
<td>2700·N lp/mm （200 lp/mm）</td>
</tr>
<tr>
<td>Eyepieces</td>
<td>12.5X</td>
</tr>
<tr>
<td>Angle between Eyepieces</td>
<td>10°</td>
</tr>
<tr>
<td>Pupillary Adjustment</td>
<td>52mm-80mm</td>
</tr>
<tr>
<td>Diopter Adjustment</td>
<td>-8D~+8D</td>
</tr>
<tr>
<td>Field of View</td>
<td>Ø36.2mm, Ø22.3mm, Ø14mm, Ø8.9mm, Ø5.7mm</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lj=e4UXj7">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>Slit Illumination</th>
</tr>
</tbody>
<tbody>
<tr>
<td>Slit Width</td>
<td>0~14mm continuous (slit becomes a circle at 14mm)</td>
</tr>
<tr>
<td>Slit Length</td>
<td>1~14mm continuous</td>
</tr>
<tr>
<td>Aperture Diameters</td>
<td>Ø14mm, Ø10mm, Ø5mm, Ø3mm, Ø2mm, Ø1mm, Ø0.2mm</td>
</tr>
<tr>
<td>Slit Angle</td>
<td>0°~180°</td>
</tr>
<tr>
<td>Slit Inclination</td>
<td>5°, 10°, 15°, 20°</td>
</tr>
<tr>
<td>Filters</td>
<td>Heat-absorbing filter, ND filter, Red-free filter, Cobalt blue filter,Yellow filter built-in</td>
</tr>
<tr>
<td>Lamp</td>
<td>LED</td>
</tr>
<tr>
<td>Luminance</td>
<td>≥150klx</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="l570W3AnV">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>Power Supply</th>
</tr>
</tbody>
<tbody>
<tr>
<td>Input Voltage</td>
<td>100V~240V</td>
</tr>
<tr>
<td>Input Frequency</td>
<td>50Hz/60Hz</td>
</tr>
<tr>
<td>Rated current</td>
<td>1.2A</td>
</tr>
<tr>
<td>Output Voltage</td>
<td>3V LED, Fixation 15V</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lNeP-tzFW">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>System Specifications</th>
</tr>
</tbody>
<tbody>
<tr>
<td>Digital Module</td>
<td>Automatic exposure/ Automatic white balance / Adjustable depth of field and aperture</td>
</tr>
<tr>
<td>Image Sensor</td>
<td>1/1.8-inch sensor / 2.4μm pixel / 5.0M Pixels</td>
</tr>
<tr>
<td>Photo Resolution</td>
<td>2592 x 1944</td>
</tr>
<tr>
<td>Frame of Video</td>
<td>25fps</td>
</tr>
<tr>
<td>Video Formats</td>
<td>MP4 H.264</td>
</tr>
<tr>
<td>Exposure Mode</td>
<td>Automatic exposure</td>
</tr>
<tr>
<td>Transmission Interface</td>
<td>USB</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lhWLnCggL">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>Packaging</th>
</tr>
</tbody>
<tbody>
<tr>
<td>Dimension</td>
<td>740mm x 450mm x 530mm(L/W/H)</td>
</tr>
<tr>
<td>Gross weight</td>
<td>23kg</td>
</tr>
<tr>
<td>Net weight</td>
<td>17kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lTbmPJEDz">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>Computer Specifications</th>
</tr>
</tbody>
<tbody>
<tr>
<td>PC configuration</td>
<td>i5-10500T 8G memory 25GB SSD+1TB storage</td>
</tr>
<tr>
<td>Display</td>
<td>1920×1080 23.8inch</td>
</tr>
<tr>
<td>PC system</td>
<td>Windows 10</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lC=UYN14J">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title">Dry Eye Module</h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>AI Non-Invasive Tear Break Up Time</th>
<th>AI Non-Invasive Tear Meniscus Height</th>
</tr>
</tbody>
<tbody>
<tr>
<td>AI identify the break-up area</td>
<td>AI identification system</td>
</tr>
<tr>
<td>Automatic first break up time</td>
<td>Automatic Non-Invasive Tear Meniscus Height</td>
</tr>
<tr>
<td>Automatic average break up time</td>
<td>Optical magnification</td>
</tr>
<tr>
<td>Visible light Placido ring projection(23 ring)</td>
<td>Electronic amplification</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lSQmxVOpg">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>AI Conjunctival Hyperemia Analysis</th>
<th>Cornea Sodium Fluorescein Staining</th>
</tr>
</tbody>
<tbody>
<tr>
<td>AI identification system</td>
<td>Eye surface damage report</td>
</tr>
<tr>
<td>Automatic conjunctival congestion percentages</td>
<td>Built-in yellow filter</td>
</tr>
<tr>
<td>Automatic ciliary congestions percentages</td>
<td>Cobalt blue filter</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="lmYwusdUa">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>AI Meibomian Glands Function Evaluation</th>
<th>Lipid Layer Thickness</th>
</tr>
</tbody>
<tbody>
<tr>
<td>AI identify Meibomian glands</td>
<td>Template comparison evaluation</td>
</tr>
<tr>
<td>Automatic Meibomian glands loss classification</td>
<td>Visible light White ring projection system</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp FlexableTable comp" data-id="ldi9frUxe">
<div class="p-txt">
<div class="al-top">
<h4 class="al-txt main-title"></h4>
<h5 class="al-txt sub-title"></h5>
</div>
</div>
<div class="al-table">
<table>
<colgroup>
<col width="50%" align="left" valign="top" />
<col width="50%" align="left" valign="top" /></colgroup>
<tbody>
<tr>
<th>Eyelid Margin</th>
<th>Dry Eye Examination Report</th>
</tr>
</tbody>
<tbody>
<tr>
<td>Optical magnification</td>
<td>Automatic analysis report</td>
</tr>
<tr>
<td>Electronic amplification</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="comp PureText comp" data-id="leUQ3JLHo">
<div class="p-txt">
<div class="al-left">
<h3 class="al-txt main-title"></h3>
<h4 class="al-txt sub-title"></h4>
</div>
</div>
</div><p>The post <a href="https://insightmedical.ca/product/mediworks-d-130-dry-eye-diagnostic-system/">Mediworks D-130 Dry Eye Diagnostic System</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tomey MR-6000 6-in-1 Multifunction Unit With Dry Eye Analysis</title>
		<link>https://insightmedical.ca/product/tomey-mr-6000-6-in-1-multifunction-unit/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=tomey-mr-6000-6-in-1-multifunction-unit</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Wed, 18 Sep 2019 22:37:12 +0000</pubDate>
				<guid isPermaLink="false">https://insightmedical.ca/?post_type=product&#038;p=9263</guid>

					<description><![CDATA[<p>What results from years of dedication, research, and development? The Tomey MR-6000 6-in-1 Multifunction unit. The MR-6000 is the most advanced multifunction unit available today featuring six different products in one streamlined easy to use machine. Experience hands free fully automated Refraction, Keratometry, Tonometry, Pachymetry, Topography, and 4 different Dry Eye analysis tools all at the single touch of a button.</p>
<p>The post <a href="https://insightmedical.ca/product/tomey-mr-6000-6-in-1-multifunction-unit/">Tomey MR-6000 6-in-1 Multifunction Unit With Dry Eye Analysis</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<p class="lead"><strong>ADVANTAGES OF THE TOMEY MR-6000:</strong></p>
<ul>
<li>Easy operation: Auto alignment and a familiar user interface</li>
<li>Space saving: Six systems in one device</li>
<li>Time saving: Change between the different modes in less than 3 seconds</li>
<li>High accuracy: Combined data of different measurements for precise results (e.g. Tono + Pachy)</li>
<li>Improved features: Softest air puff control and enhanced refraction functionality.</li>
<li>Complete dry eye analysis: Combination of 4 different measurements including Meibography, Blink Frequency, Hyperamia, and Tear Film Height.</li>
<li>Minimize your complete examintation time down to just 90 seconds for measurement of Refraction + Keratometry + Tonometry + Pachymetry + Topography.</li>
</ul>
<p><strong>REFRACTION + KERATOMETRY:</strong><br />
Get accurate measurement values for Refraction and Keratometry due to an improved measurement principle.</p>
<p><strong>QUICK REFRACTION MODE:</strong><br />
The Quick Refraction Mode allows refraction values within seconds despite Fixation loss e.g. for patients with Nystagmus, Children or uncooperative patients.</p>
<p><strong>TONOMETRY + PACHYMETRY:</strong><br />
A new Generation of air flow Technology causes a friendly and gentle air puff.<br />
The automated IOP correction is taking account of Pachymetry values to get reliable IOP values</p>
<p><strong>TOPOGRAPHY:</strong><br />
16 Mires Rings examine an area of 8mm Diameter. Several map types including Fourier Analysis lead to a wide range of corneal shape displaying opportunities.</p>
<p><strong>DRY EYE OBSERVATION SOFTWARE:</strong><br />
The combination of 4 examinations gives a detailled Impression of the Health of the patients´ ocular Surface. Observe the blinking frequency, tear meniscus height, Hyperemia and Meibomian Glands by using only one medical device.</p><p>The post <a href="https://insightmedical.ca/product/tomey-mr-6000-6-in-1-multifunction-unit/">Tomey MR-6000 6-in-1 Multifunction Unit With Dry Eye Analysis</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mediworks S390L Firefly WDR Digital Anterior Segment and Meibography Slit Lamp</title>
		<link>https://insightmedical.ca/product/mediworks-s391l-firefly-wdr-digital-anterior-segment-and-meibography-slit-lamp/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=mediworks-s391l-firefly-wdr-digital-anterior-segment-and-meibography-slit-lamp</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Mon, 14 Jan 2019 23:55:42 +0000</pubDate>
				<guid isPermaLink="false">https://insightmedical.ca/?post_type=product&#038;p=9190</guid>

					<description><![CDATA[<p>"<strong><em>Simply capture every key moment</em></strong>"</p>
<p>The Mediworks S390L Firefly is premier tower style slit lamp built with exceptional quality at an affordable price. Featuring built in digital imaging controls, crisp optics ranging from 6x-40x magnification (6x, 10x, 16x, 25x, 40x) on a 5 step drum, LED illumination, a full complement of filters, fixed and variable slit length/apertures and the ability to facilitate accessories such as a Goldmann tonometers.</p>
<p>The post <a href="https://insightmedical.ca/product/mediworks-s391l-firefly-wdr-digital-anterior-segment-and-meibography-slit-lamp/">Mediworks S390L Firefly WDR Digital Anterior Segment and Meibography Slit Lamp</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><i>MediWorks was started in 2004 with the belief that the finest details will make the most meaningful difference in the user experience. The Mediworks team consists of several experienced mechanical, ophthalmic, software, electronic and algorithmic engineers that specialize in the eye care industry. The team works relentlessly to pursue products with a practical design to bring users exceptional quality products. With more than ten years of development, MediWorks has now created a series of ophthalmic diagnostic equipment with extremely reliable quality and breakthrough technology. &#8220;We understand that there is still a long way to go for us to become an industry leader, however we will never stop our efforts to reach this goal.&#8221;</i></p>
<p><strong>Simple Design + Simple Operation</strong><br />
The design is widely inspired off that of a Firefly. This smart design saves space for doctors compared to other bulky DSLR camera systems attached with an aftermarket beamsplitter. The Firefly is ready to use right out of the box with a handful of preset camera parameters so the user does not need to adjust settings before use.</p>
<p><strong>Software Features</strong><br />
When equipped with the included MediView software, the Mediworks Firefly is capable of Anterior segment imaging and analysis, Meibography imaging, Tear Film breakup time, Tear Meniscus height, Orthokeratology Lens Fitting Assistance, red eye analysis, Keratopathy exposure, and much more. Mediview Software features an intuitive patient management system enabling clinicians to build and edit patient records, clinicians can easily record symptoms and manage the data all the time.</p>
<p><strong>Adjustable Aperture<br />
</strong>The aperture can be adjusted to 6 different levels to meet a variety of depth and brightness settings.</p>
<p><img fetchpriority="high" decoding="async" class="fr-draggable fr-dii" src="http://www.mediworks.biz/attachments/editor/20161013071256322.jpg" width="475" height="189" /></p>
<p><strong>HDMI output<br />
</strong>The built in HDMI output can be used to connect the S390L slit lamp to any compatible monitor. You can then share the live eye examination status simultaneously with patient’s, or students for teaching purpose.</p>
<p><img decoding="async" class="fr-draggable fr-dii alignnone" src="http://www.mediworks.biz/attachments/editor/20161013070752637." width="476" height="247" /></p>
<p><b>Easier Installation &amp; Quick Capture Button</b><br />
The S390L Firefly features a compact control panel with built-in power supply making for an extremely clean installation of the slit lamp without leaving behind a mess of cables. Because of such, there is no need to find space to install a chunky power box.<b> </b>There is a convenient button on the control panel that enables you to shoot photos quickly and easily. Once you&#8217;ve captured a suitable photo to describe the pathology, simply press the capture button once more and the image will be saved to the patients record in the Mediview database.</p>
<p><img decoding="async" class="fr-dib fr-draggable alignnone" src="http://www.mediworks.biz/attachments/editor/20170223065034115." width="475" height="333" data-ok="true" /></p>
<p><b>Coaxial Illuminator<br />
</b>The new LED background illuminator is positioned coaxially to the microscope without getting in the way of the rest of the slit lamps. It provides an adjustable circular beam of light to enhance the digital capturing effect.</p>
<p><img loading="lazy" decoding="async" class="fr-dib fr-draggable" src="http://www.mediworks.biz/attachments/editor/20170223070543289." width="476" height="340" data-ok="true" /></p>
<p><b>Less Cables with Extra USB Port<br />
</b>Thanks to the built in control panel, there is no longer a need for exposed cables outside the microscope. Additionally the control panel features an extra USB port to conveniently charge other-medical devices simultaneously.</p>
<p><img loading="lazy" decoding="async" class="fr-dib fr-draggable" src="http://www.mediworks.biz/attachments/editor/20170223070926583." width="475" height="333" data-ok="true" /></p>
<p><strong>Optical resolution increased by 40%</strong><b><br />
</b>The newly improved high quality oculars make for an extraordinary resolution that exceeds the requirements of any doctor allowing for better accuracy and safer diagnostic results.</p>
<p><img loading="lazy" decoding="async" class="fr-draggable fr-dii" src="http://www.mediworks.biz/attachments/editor/20181019092620726.jpg" width="475" height="328" data-ok="true" /></p>
<p><strong>Ultra-sensitive camera</strong></p>
<p>1/1.8” Sensor          2592 x 1944                    25fps<br />
<img loading="lazy" decoding="async" class="fr-dib fr-draggable fr-fil" src="http://www.mediworks.biz/attachments/editor/20181022021304122.png" width="330" height="79" data-ok="true" /><br />
1/4” Sensor             1280 x 960                      12fps</p>
<p><img loading="lazy" decoding="async" class="fr-draggable fr-dii" src="http://www.mediworks.biz/attachments/editor/20181019092634920.jpg" width="476" height="328" data-ok="true" /></p>
<p><strong>The Meibomian glands examination</strong><strong><br />
</strong>The unique built in infrared light source module allows for the observation of the patient&#8217;s Meibomian glands. This helps in understanding the absence of a patient&#8217;s Meibomian glands, and thus determines the lesion of the patient&#8217;s dry eye syndrome.</p>
<p><img loading="lazy" decoding="async" class="fr-dib fr-draggable fr-fil" src="http://www.mediworks.biz/attachments/editor/20181019092648325.jpg" width="477" height="328" data-ok="true" /></p>
<p><strong>Built-in yellow filter</strong><b><br />
</b>The built-in yellow filter helps to get a clear tissue image with enhanced contrast. The yellow filter is also necessary for the orthokeratology lenses fitting.</p>
<p><img loading="lazy" decoding="async" class="fr-dib fr-draggable fr-fil" src="http://www.mediworks.biz/attachments/editor/20181019092653321.jpg" width="474" height="324" data-ok="true" /></p>
<table class="fr-alternate-rows" style="height: 843px;" border="0" width="602" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2" width="606" height="18"><strong>Microscope Specifications</strong></p>
<hr />
</td>
</tr>
<tr>
<td></td>
<td height="18">Microscope:</td>
<td>Galilean Type</td>
</tr>
<tr>
<td></td>
<td height="18">Magnification Change:</td>
<td>Revolving Drum 5 steps</td>
</tr>
<tr>
<td></td>
<td height="18">Total Magnification:</td>
<td>6X, 10X, 16X, 25X, 40X</td>
</tr>
<tr>
<td></td>
<td height="18">Eyepieces:</td>
<td>12.5X</td>
</tr>
<tr>
<td></td>
<td height="18">Angle between Eyepieces:</td>
<td>13°</td>
</tr>
<tr>
<td></td>
<td height="18">Pupillary Adjustment:</td>
<td>52 mm-78 mm</td>
</tr>
<tr>
<td></td>
<td height="18">Diopter Adjustment:</td>
<td>±8D</td>
</tr>
<tr>
<td></td>
<td>Field of View:</td>
<td>Ø36.2mm, Ø22.3mm, Ø14mm, Ø8.9mm, Ø5.6mm</td>
</tr>
<tr>
<td></td>
<td height="18"></td>
<td></td>
</tr>
<tr>
<td></td>
<td colspan="2" height="18"><strong>Slit Illumination:</strong></p>
<hr />
</td>
</tr>
<tr>
<td></td>
<td height="34">Slit Width:</td>
<td width="341">0~14 mm continuous  (slit becomes a circle at 14 mm)</td>
</tr>
<tr>
<td></td>
<td height="18">Slit Length:</td>
<td>1~14 mm continuous</td>
</tr>
<tr>
<td></td>
<td height="34">Aperture Diameter:</td>
<td width="341">Φ14 mm, Φ10 mm, Φ5 mm, Φ3 mm,  Φ2 mm, Φ1 mm, Φ0.2 mm</td>
</tr>
<tr>
<td></td>
<td height="18">Slit Angle:</td>
<td>0°~180°</td>
</tr>
<tr>
<td></td>
<td height="18">Slit Inclination:</td>
<td>5°, 10°, 15°, 20°</td>
</tr>
<tr>
<td></td>
<td height="34">Filters:</td>
<td width="341">Heat-absorbing filter, ND filter, Red-free filter, Cobalt Blue filter,Yellow filter built-in</td>
</tr>
<tr>
<td></td>
<td height="18">Lamp:</td>
<td>3V LED Module</td>
</tr>
<tr>
<td rowspan="2"></td>
<td height="18">Luminance:</td>
<td height="18">≥150KLX</td>
</tr>
<tr>
<td colspan="2" height="18"></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p><p>The post <a href="https://insightmedical.ca/product/mediworks-s391l-firefly-wdr-digital-anterior-segment-and-meibography-slit-lamp/">Mediworks S390L Firefly WDR Digital Anterior Segment and Meibography Slit Lamp</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tomey RT-7000 Autorefractor/Keratometer/Topographer/Dry Eye</title>
		<link>https://insightmedical.ca/product/tomey-rt-7000-autorefractor-keratometer-topographer-dry-eye/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=tomey-rt-7000-autorefractor-keratometer-topographer-dry-eye</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Tue, 19 Apr 2016 19:02:11 +0000</pubDate>
				<guid isPermaLink="false">http://insightmedical.ca/?post_type=product&#038;p=8631</guid>

					<description><![CDATA[<p><span class="got">The Auto Ref-Topographer RT-7000 is a 3-in-1 hybrid system consisting of an Auto Refractmeter, an Auto Keratometer and a Corneal Topographer. The most remarkable clinical applications of the RT-7000 are the “Tear Stability Analysis System (TSAS)” and the “Fourier Analysis map”. The TSAS interprets the changes of the mire rings’ distortion on an eye opened for 6 seconds as changes of its tear layer status and displays color code maps to illustrate the locations of those changes. On the other hand, the newly implemented “Fourier Analysis map” performs Fourier analysis for refractive powers at individual measurement points obtained by analyzing Mire images within the ø3 mm range and ø6 mm range, and visually and quantitatively displays the constant term (the spherical component), the first order term (the asymmetry component), the second order term (the regular astigmatism component), and the higher order terms (the higher order irregularity).</span></p>
<p>The post <a href="https://insightmedical.ca/product/tomey-rt-7000-autorefractor-keratometer-topographer-dry-eye/">Tomey RT-7000 Autorefractor/Keratometer/Topographer/Dry Eye</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-canvas-width="81.855">A unique combination of Topography, autorefraction, Kerato-metry and TSaS (tear stability analysis system) in one – multi diagnostic replaces four devices with all their functions. The compactness of this instrument is its strength. it is therefore a perfect space and cost saving solution for you. highly accurate measurements combined with the short examination time and easy handling makes working with the RT-7000 professional</div>
<div data-canvas-width="60.75">and quick.</div>
<div data-canvas-width="60.75"></div>
<h3 data-canvas-width="125.02499999999996">Colour touch screen</h3>
<div data-canvas-width="48.794999999999995">The 6.4 inch coloured touch screen is used as operating monitor as well as for displaying all measured values. You can even move the unit in all directions by simply touching the screen. All commands can be done via touch screen. Auto alignment + auto shot The handling of the RT-7000</div>
<div data-canvas-width="401.415">is very easy – it does almost every- thing by itself. Alignment and measurement are done automatically. You just roughly align the system towards the patient eye and the rest is taken care of by the instrument.</div>
<div data-canvas-width="401.415"></div>
<h3 data-canvas-width="401.415">Tear stability analysis system</h3>
<div data-canvas-width="146.01">Tear stability analysis system for analysing the tear film stability by using the light cone system in the RT-7000. That offers you several</div>
<div data-canvas-width="84.87">measurement and analysing functions to detect patients with dry eye indication.</div>
<div data-canvas-width="84.87"></div>
<h3 data-canvas-width="195.26999999999998">Pupil + cornea ø measurement</h3>
<div data-canvas-width="400.875">Once you have captured your patients eye you can set the pupil and cornea measurement bars to measure the individual diameter. Topography indices KRI + KAI for immediate understanding of the cornea topographic structure we have implemented the topographic indices Kai (Kerato-asymetry index) and KRi (Kerato-Regularity index). These values are highlighted in colour (green = normal, yellow = suspect, red = abnormal) to</div>
<div data-canvas-width="397.62">provide you a quick information about the corneal structure behaviour.</div><p>The post <a href="https://insightmedical.ca/product/tomey-rt-7000-autorefractor-keratometer-topographer-dry-eye/">Tomey RT-7000 Autorefractor/Keratometer/Topographer/Dry Eye</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>