<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Ophthalmic Ultrasound - Insight Medical Technologies</title>
	<atom:link href="https://insightmedical.ca/product-category/diagnostic-equipment/ophthalmic-ultrasound/feed/" rel="self" type="application/rss+xml" />
	<link>https://insightmedical.ca</link>
	<description>Your Consultative Ophthalmic Equipment Dealer Since 2009</description>
	<lastBuildDate>Mon, 30 Mar 2020 20:00:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>

<image>
	<url>https://insightmedical.ca/wp-content/uploads/2017/08/cropped-Logo-HQ-32x32.jpg</url>
	<title>Ophthalmic Ultrasound - Insight Medical Technologies</title>
	<link>https://insightmedical.ca</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Tomey UD-800 Modular A/B Scan System</title>
		<link>https://insightmedical.ca/product/tomey-ud-800-modular-a-b-scan-system/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=tomey-ud-800-modular-a-b-scan-system</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Fri, 27 Mar 2020 22:04:59 +0000</pubDate>
				<guid isPermaLink="false">https://insightmedical.ca/?post_type=product&#038;p=9411</guid>

					<description><![CDATA[<p>The UD-800 is a compact all-in-one device with high resolution. In addition to the main B-scan, you can add UBM, Biometry, Pachymetry and A-Scan Diagnosis as options. Harmonic function is also available with B-Scan.</p>
<p>The post <a href="https://insightmedical.ca/product/tomey-ud-800-modular-a-b-scan-system/">Tomey UD-800 Modular A/B Scan System</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<div class="contProdDes">
<p class="lead">All in one. For complete ultrasound diagnostic needs.</p>
<p>B-scanner, Biometer, Pachymeter and A-Diagnostic – all in one.</p>
<p>The UD-800 was developed to satisfy all your expectations. Features like the new generation of annular array probes, high resolution touch-screen operation or data communication via USB or LAN makes this device easy in handling and efficient and fast in operation. Simply choose all your needed features! With its included 10 MHz unique 2-ring array B-Scan probe and the A-Scan biometry probe the UD-800 is a fantastic basic tool for a high end performance.</p>
<p>An intuitive software guides you easily through all measurements, which can be printed out (internal printer as well as external printer). Or just simply save the data on the internal database or on the PC. With the DICOM conform export hospital networks are no problem anymore or just simple pure data export, it is your choice.</p>
<table class="table table-bordered">
<tbody>
<tr>
<td>Modular configurable</td>
<td>Pachymetry (optional)</td>
</tr>
<tr>
<td>Internal database</td>
<td>UBM 40 MHz B-probe (optional)</td>
</tr>
<tr>
<td>Biometer A-scan 10 MHz</td>
<td>A-diagnostic probe (optional)</td>
</tr>
<tr>
<td>10 MHz 2-ring array B-probe</td>
<td>Connectable to OA-2000</td>
</tr>
</tbody>
</table>
<div class="row">
<div class="col-sm-6">
<div class="panel panel-primary">
<div class="panel-body">
<h4 class="text-primary">Complete probe selection</h4>
<p>Decide for more options now or later – with the optional 40 MHz linear UBM or 20 MHz Pachymetry probe – they are all easy to attach. Even A-diagnostic with the log, linear or S-mode is no problem.</p>
<p><img decoding="async" class="img-thumbnail" src="http://www.mercoframes.net/images/data/gall_1c43e6.jpg" alt="" /></div>
</div>
</div>
<div class="col-sm-6">
<div class="panel panel-primary">
<div class="panel-body">
<h4 class="text-primary">Unique 10 MHZ 2-ring array B-probe</h4>
<p>Advanced vitreous diagnostic examination due to our new optimised wide field tissue penetration mode.</p>
<p><img decoding="async" class="img-thumbnail" src="http://www.mercoframes.net/images/data/gall_593c17.jpg" alt="" /></div>
</div>
</div>
</div>
<div class="row">
<div class="col-sm-6">
<div class="panel panel-primary">
<div class="panel-body">
<h4 class="text-primary">40 MHZ UBM (OPTIONAL)</h4>
<p>Membrane waterproofed cap (disposable) provides fast and easy testing without the need of a water bath. Due to this technology you are able to examine your patient in an upright position with much more comfort – for you and your patient.</p>
<p><img decoding="async" class="img-thumbnail" src="http://www.mercoframes.net/images/data/gall_be4329.jpg" alt="" /></div>
</div>
</div>
<div class="col-sm-6">
<div class="panel panel-primary">
<div class="panel-body">
<h4 class="text-primary">INTERNAL DATABASE</h4>
<p>You can simply save the data on the internal database or on the PC.<br />
Intuitive software guides all measurement results, which can be printed out through built-in printer or external printer.<br />
It is also possible to save the data (up to 52,000 eyes) on the internal database and the PC as well. With the DICOM format, hospital intranetworks become efficient. Data export (CSV or JPEG) is available.</p>
<p><img decoding="async" class="img-thumbnail" src="http://www.mercoframes.net/images/data/gall_b877f8.jpg" alt="" /></div>
</div>
</div>
</div>
<div class="row">
<div class="col-sm-6">
<div class="thumbnail"><img decoding="async" src="http://www.mercoframes.net/images/data/gall_f142a7.jpg" alt="" /></p>
<div class="caption">
<h3>Biometry</h3>
</div>
</div>
</div>
<div class="col-sm-6">
<div class="thumbnail"><img decoding="async" src="http://www.mercoframes.net/images/data/gall_4d7dae.jpg" alt="" /></p>
<div class="caption">
<h3>IOL calculation</h3>
</div>
</div>
</div>
<div class="col-sm-6">
<div class="thumbnail"><img decoding="async" src="http://www.mercoframes.net/images/data/gall_790d39.jpg" alt="" /></p>
<div class="caption">
<h3>Standardised A-diagnostic with S-mode</h3>
</div>
</div>
</div>
<div class="col-sm-6">
<div class="thumbnail"><img decoding="async" src="http://www.mercoframes.net/images/data/gall_b01f18.jpg" alt="" /></p>
<div class="caption">
<h3>Pachymetry with central and map function</h3>
</div>
</div>
</div>
</div>
<h2>Specifications</h2>
<div class="row">
<div class="col-sm-6">
<table class="table table-bordered table-condensed">
<tbody>
<tr>
<td class="danger" colspan="2">
<h3>10 MHZ B-PROBE<br />
2-RING SECTOR SCANNING</h3>
</td>
</tr>
<tr>
<td>Frame rate basic mode</td>
<td>20 frames / sec</td>
</tr>
<tr>
<td>Maximum number of pages in a movie</td>
<td>200 pages x 2</td>
</tr>
<tr>
<td>Image display range Standard</td>
<td>35.2 mm / 52° (at ultrasound velocity = 1,550 m / sec)</td>
</tr>
<tr>
<td>Wide</td>
<td>48.0 mm / 52° (at ultrasound velocity = 1,550 m / sec)</td>
</tr>
<tr>
<td>Axial &amp; lateral resolution / accuracy</td>
<td>0.6 mm / ±0.5 mm</td>
</tr>
<tr>
<td>Acoustic lines</td>
<td>131 lines (step by 0.4°)</td>
</tr>
<tr>
<td>Colour scale</td>
<td>256 scale level</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>40 MHZ UBM PROBE<br />
SINGLE LINEAR SCANNING</h3>
</td>
</tr>
<tr>
<td>Frame rate basic mode</td>
<td>10 frame / sec</td>
</tr>
<tr>
<td>Maximum number of pages in a movie</td>
<td>100 pages x 2</td>
</tr>
<tr>
<td>Image display range</td>
<td>9 mm (W) x 7mm (D) (at 1,550 m / sec)</td>
</tr>
<tr>
<td>Axial &amp; lateral resolution / accuracy</td>
<td>0.05 mm / ±0.1 mm</td>
</tr>
<tr>
<td>Minimum distance unit between cursors</td>
<td>0.02 mm step (at 1,550 m / sec)</td>
</tr>
<tr>
<td>Acoustic lines</td>
<td>450 lines (step by 0.02 mm)</td>
</tr>
<tr>
<td>Colour scale</td>
<td>256 scale level</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>BIOMETRY 10 MHZ SOLID STATE PROBE WITH BUILT IN RED FIXATION LED</h3>
</td>
</tr>
<tr>
<td>Measurement range</td>
<td>45.00 mm</td>
</tr>
<tr>
<td>Measurement resolution / accuracy</td>
<td>0.01 mm / ±0.1 mm</td>
</tr>
<tr>
<td>IOL power calculation</td>
<td>Haigis standard<br />
Haigis optimised<br />
Hoffer ®Q<br />
Holladay 1<br />
SRK II<br />
SRK/T<br />
SRK SHOWA<br />
Shammas-PL<br />
SRK/T Double K</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>A-SCAN DIAGNOSIS 10 MHZ SOLID STATE PROBE</h3>
</td>
</tr>
<tr>
<td>Measurement range</td>
<td>60 mm</td>
</tr>
<tr>
<td>Measurement resolution / accuracy</td>
<td>0.01 mm / ±0.1 mm</td>
</tr>
</tbody>
</table>
</div>
<div class="col-sm-6">
<table class="table table-bordered table-condensed">
<tbody>
<tr>
<td class="danger" colspan="2">
<h3>PACHYMETRY 20 MHZ SOLID STATE PROBE<br />
TIP 1.5 MM WITH AN ANGLE OF 45°</h3>
</td>
</tr>
<tr>
<td>Measurement range</td>
<td>150 to 1,500 μm</td>
</tr>
<tr>
<td>Measurement resolution / accuracy</td>
<td>1 μm / ±5 μm</td>
</tr>
<tr>
<td>Percent bias</td>
<td>60 to 130%</td>
</tr>
<tr>
<td>Plus minus bias</td>
<td>-600 to +450 μm</td>
</tr>
<tr>
<td>Velocity range / standard</td>
<td>1,400 to 2,000 m/s / 1,640 m/s</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>CONNECTORS</h3>
</td>
</tr>
<tr>
<td class="info" colspan="2">
<h4>B-scan for 10 or 40 MHz, a-scan / pachymeter, foot switch, LAN, USB 2 x standard 2 x OA-2000/PicBrigde</h4>
</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>DIMENSIONS AND WEIGHT</h3>
</td>
</tr>
<tr>
<td>Dimension WDH</td>
<td>310 x 214 x 326 mm</td>
</tr>
<tr>
<td>Weight</td>
<td>6.0 kg</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>DISPLAY</h3>
</td>
</tr>
<tr>
<td>TFT LCD</td>
<td>10.4 inches, colour touch screen</td>
</tr>
<tr>
<td class="danger" colspan="2">
<h3>POWER SOURCE</h3>
</td>
</tr>
<tr>
<td>Input Voltage</td>
<td>100-240 VAC</td>
</tr>
<tr>
<td>Frequency</td>
<td>50 / 60 Hz</td>
</tr>
<tr>
<td>Power consumption</td>
<td>120 VA</td>
</tr>
</tbody>
</table>
<p><a class="thumbnail fancybox" href="http://www.mercoframes.net/images/data/o_1a01cir961on1uvj1smk1dsu18ovb.jpg"><img decoding="async" src="http://www.mercoframes.net/images/data/o_1a01cir961on1uvj1smk1dsu18ovb.jpg" alt="" /></a></div>
</div>
</div>
<div id="attach">
<div id="files" class="panel panel-default">
<div class="panel-heading"></div>
</div>
</div><p>The post <a href="https://insightmedical.ca/product/tomey-ud-800-modular-a-b-scan-system/">Tomey UD-800 Modular A/B Scan System</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tomey OA-2000 Optical Biometer</title>
		<link>https://insightmedical.ca/product/tomey-oa-2000-optical-biometer/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=tomey-oa-2000-optical-biometer</link>
		
		<dc:creator><![CDATA[insightmedical]]></dc:creator>
		<pubDate>Fri, 22 Apr 2016 13:42:37 +0000</pubDate>
				<guid isPermaLink="false">http://insightmedical.ca/?post_type=product&#038;p=8639</guid>

					<description><![CDATA[<p>The Optical Biometer OA-2000 provides non-contact, non-invasive and automatic measurement of the axial length (Axial), anterior chamber depth (ACD), lens thickness(Lens) and central corneal thickness (CCT) based on fourier domain technology. The OA-2000 integrates topography by ring cone to measure radius of corneal curvature, and corneal shape</p>
<p>The post <a href="https://insightmedical.ca/product/tomey-oa-2000-optical-biometer/">Tomey OA-2000 Optical Biometer</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><em><strong>Fourier domain axial length measurement + topography</strong></em><br />
The Fourier domain method is used as a measuring method thar features high-speed superior tissue penetration. Equipped with a search function that automatically detects a measurable point even when the crystal lens is unclear.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_6.jpg" alt="" /><br />
The ring cone method is used to measure the radius of corneal curvature.<br />
In addition to the ø3.0 mm position measured by a general keratometer, ø2.5 mm and ø2.0 mm positions are also simultaneously measured.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_8.jpg" alt="" /><br />
Also, up to ø5.5 mm of the cornea is captured and the topography(corneal shape map) is drawn using the ring cone method. The topography is useful for checking eyes after LASIK sugery or corneal irregular astigmatism, or observing the variation<br />
in the corneal shape before and after the surgery. It is also equipment with a function that supports the axis where the toric intraocular lens is to be inserted in the cataract surgery.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_9.jpg" alt="" /></p>
<p><em><strong>IOL power calculation function</strong></em><br />
The OA-2000 is standard equipped with mine IOL power formulas, including two formulas for eyes after LASIK surgery. Up to 15 types of lens can be registred.</p>
<p>&nbsp;</p>
<p><em><strong>Nine formulas</strong></em><br />
SRK-II formula, SRK/T formula, HOLLADAY formula, Hoffer Q formula, HAIGIS optimized formula, HAIGIS standard formula, SRK SHOWA formula, &lt;formulas exclusively for eyes after LASIK surgery&gt; Double K SRK/T, Shammas-PL formula ( Will be supported on &#8220;OKULIX&#8221; &#8220;EASY IOL&#8221;)</p>
<p><em><strong>Enhanced usability</strong></em><br />
In spite of a size that allows the unit to be installed on a compact optical bench, it is equipped with a 10.4-inch large monitor with a tilting function that adjusts the position to the level of physician´s eyes.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_3.jpg" alt="" /></p>
<p>Simply touching the center of the pupil displayed on the monitor screen begins alignment. Measurement stars inmediately via the Auto Alignment and Auto Short functions. Even  when the physician operates the unit for the first time, intuitive operation is possible. In the event that automatic measurement is difficult, manual measurement is possible using an electric joystick.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_4.jpg" alt="" /></p>
<p><em><strong>Connection with ultrasonic measurement unit</strong></em><br />
In cases where optical measurement is difficult due to blood in the eyes or other issues, the OA-2000 can be connected wirelessly to the ultrasonic axial length measurement unit AL-4000.<br />
IOL power calculation, data storage and other operations can be performed on the main unit of the OA-2000.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_5.jpg" alt="" /></p>
<p><em><strong>One-shot IOL power calculation</strong></em><br />
Up to seven sets of measurement data, such as the corneal thickness and anterior chamber depth in addition to the axial length and corneal curvature, can be obtained in one shot time.A series of operations from th examination before cataract surgery to the management after surgery can be performed with one OA-2000, including IOL power calculation, post-surgery data storage, A-constant optimization, and statical processing.</p>
<p><img decoding="async" src="http://optimetrics.com/store/media/wysiwyg/OA-2000_6.jpg" alt="" /></p><p>The post <a href="https://insightmedical.ca/product/tomey-oa-2000-optical-biometer/">Tomey OA-2000 Optical Biometer</a> first appeared on <a href="https://insightmedical.ca">Insight Medical Technologies</a>.</p>]]></content:encoded>
					
		
		